Model LC300 - Model 90550
Automated blood pressure and heart-rate monitoring in a compact, space-saving design.
Providing Value For
Companies of all sizes promoting wellness to improve the health of their employees and reduce healthcare costs
Pharmacies as a community service enhancing professional image, prescription business and customer loyalty
Hospital outpatient clinics, busy doctors’ offices and dental practices to obtain reliable vital sign readings with minimal staff assistance
Fitness centers to provide a valuable and popular member service before and after workouts
Community and organizational outreach programs
Senior centers, retirement communities and anywhere people gather
Features
Blood Pressure and Pulse Rate
Proven Accuracy
Fully-Automated Upper-Arm Pressure Cuff
LED Display of Readings
Blood Pressure Guidelines Display
Oscillometric Methodology
Four Information Display Panels
User Record Card Holder
Specifications
Equipment
Class II medical device manufactured in FDA-regulated NYBP facility
Accuracy
Complies with AAMI (Association for the Advancement of Medical Instrumentation) Standards
+/- 5 mmHg (millimeters of mercury)
Temperature
Operating: 50 to 104° F (10 to 40° C)
Storage: -40 to 131° F (-40 to 55° C)
Humidity
Operating: 10 to 95% (noncondensing)
Storage: 10 to 95% (noncondensing)
Digital Displays
Systolic & diastolic pressure, pulse rate
Rate of Cuff Inflation
Approximately 8 mmHg/sec
Measurement Range
Systolic: +50 to +260 mmHg
Diastolic: +30 to +240 mmHg
Pulse: 40 bpm to 199 bpm
Measurement Method
Oscillometric
Overpressure Limit
310 +/- 10 mmHg
Test Time
Typically less than one minute
Input Power Requirements
117 VAC
60Hz
2.5 amps
3-wire grounded outlet
Physical Dimensions
Height: 68.0 in. (170.0 cm)
Width: 26.1 in. (66.4 cm)
Depth: 22.2 in. (56.4 cm)
Weight: 90 lbs (45.5 kg)
An interactive health station capable of Internet-connectivity
Features
Blood Pressure, Pulse Rate and Weight
Fully-Automated Upper-Arm Pressure Cuff
Oscillometric Methodology
Proven Accuracy Meets AAMI Standards
Electronic Scale
10.4” Touchscreen LCD Display
Optionalheelchair Accessibility
Interactive Health Information Screens
Color-Coded Results Charts
Four Information Display Panels
Specifications
Equipment
Class II medical device manufactured in FDA-regulated NYBP facility
Blood Pressure Measurement
Measurement Method
Oscillometric
Accuracy
Complies with AAMI (Association for the Advancement of Medical Instrumentation) Standards
+/- 5 mmHg (millimeters of mercury)
Range
Systolic: +50 to +260 mmHg
Diastolic: +30 to +240 mmHg
Pulse: 40 bpm to 199 bpm
Rate of Cuff Inflation
Approximately 8 mmHg/sec
Overpressure Limit
310 +/- 10 mmHg
Temperature
Operating: 50 to 104° F (10 to 40° C)
Storage: -40 to 131° F (-40 to 55° C)
Humidity
Operating: 10 to 95% (noncondensing)
Storage: 10 to 95% (noncondensing)
Weight Measurement
Range: 40 to 440 lbs.
Accuracy: +/- 1 lb.
Input Power Requirements
117 VAC, 60Hz
2.5 amps
3-wire grounded outlet
Physical Dimensions
Height: 9.0 in. (22.9 cm)
Width: 19.5 in. (49.6 cm)
Depth: 10.5. (26.7 cm)
Weight: 12 lbs (5.5 kg)