Model LC300 - Model 90550

Automated blood pressure and heart-rate monitoring in a compact, space-saving design.

Providing Value For

Companies of all sizes promoting wellness to improve the health of their employees and reduce healthcare costs

Pharmacies as a community service enhancing professional image, prescription business and customer loyalty

  • Hospital outpatient clinics, busy doctors’ offices and dental practices to obtain reliable vital sign readings with minimal staff assistance

  • Fitness centers to provide a valuable and popular member service before and after workouts

  • Community and organizational outreach programs

  • Senior centers, retirement communities and anywhere people gather

Features

Blood Pressure and Pulse Rate

Proven Accuracy

Fully-Automated Upper-Arm Pressure Cuff

LED Display of Readings

Blood Pressure Guidelines Display

Oscillometric Methodology

Four Information Display Panels

User Record Card Holder

Specifications

Equipment

Class II medical device manufactured in FDA-regulated NYBP facility

Accuracy

Complies with AAMI (Association for the Advancement of Medical Instrumentation) Standards

+/- 5 mmHg (millimeters of mercury)

Temperature

Operating: 50 to 104° F (10 to 40° C)

Storage: -40 to 131° F (-40 to 55° C)

Humidity

Operating: 10 to 95% (noncondensing)

Storage: 10 to 95% (noncondensing)

Digital Displays

Systolic & diastolic pressure, pulse rate

Rate of Cuff Inflation

Approximately 8 mmHg/sec

Measurement Range

Systolic: +50 to +260 mmHg

Diastolic: +30 to +240 mmHg

Pulse: 40 bpm to 199 bpm

Measurement Method

Oscillometric

Overpressure Limit

310 +/- 10 mmHg

Test Time

Typically less than one minute

Input Power Requirements

117 VAC

60Hz

2.5 amps

3-wire grounded outlet

Physical Dimensions

Height: 68.0 in. (170.0 cm)

Width: 26.1 in. (66.4 cm)

Depth: 22.2 in. (56.4 cm)

Weight: 90 lbs (45.5 kg)

 

An interactive health station capable of Internet-connectivity

Features

Blood Pressure, Pulse Rate and Weight

Fully-Automated Upper-Arm Pressure Cuff

Oscillometric Methodology

Proven Accuracy Meets AAMI Standards

Electronic Scale

10.4” Touchscreen LCD Display

Optionalheelchair Accessibility

Interactive Health Information Screens

Color-Coded Results Charts

Four Information Display Panels

Specifications

Equipment

Class II medical device manufactured in FDA-regulated NYBP facility

Blood Pressure Measurement

Measurement Method

Oscillometric

Accuracy

Complies with AAMI (Association for the Advancement of Medical Instrumentation) Standards

+/- 5 mmHg (millimeters of mercury)

Range

Systolic: +50 to +260 mmHg

Diastolic: +30 to +240 mmHg

Pulse: 40 bpm to 199 bpm

Rate of Cuff Inflation

Approximately 8 mmHg/sec

Overpressure Limit

310 +/- 10 mmHg

Temperature

Operating: 50 to 104° F (10 to 40° C)

Storage: -40 to 131° F (-40 to 55° C)

Humidity

Operating: 10 to 95% (noncondensing)

Storage: 10 to 95% (noncondensing)

Weight Measurement

Range: 40 to 440 lbs.

Accuracy: +/- 1 lb.

Input Power Requirements

117 VAC, 60Hz

2.5 amps

3-wire grounded outlet

Physical Dimensions

Height: 9.0 in. (22.9 cm)

Width: 19.5 in. (49.6 cm)

Depth: 10.5. (26.7 cm)

Weight: 12 lbs (5.5 kg)

Model LC500